September 18, 2015

Waste Oil Boilers

clean-burn-logoWaste Oil Boilers

Clean Burn waste oil fired boilers are your best choice for economical and plentiful hot water for car and truck washes, radiant floor heat, space heat, snow/ice melting, and industrial processing.

The Clean Burn line of coil tube used oil boilers are engineered from the ground up to burn waste oils. They will efficiently recycle your used oil as a free fuel source to generate hot water, and are remarkably versatile for a wide range of applications, such as car wash facilities, baseboard heating, space heating, in-floor heating and ice melt applications. The Clean Burn coil tube boiler systems are robust and reliable and can be used as a single boiler unit, or as a part of a series of boilers working as a larger system.

Clean Burn CTB-200
200,000 btu used oil boiler
200,000 btu used oil boiler
CTB-200 Specifications
Maximum BTU/hr (output) 200,000 /58.6 kW
Max. oil consumption/ Fuel flow rate 1.4 GPH / 5.3 L/h
Acceptable Fuels Crankcase Oil, ATF, #2, #4, and #5 fuel oils, diesel oil and diesel fuel, synthetic used oil
Heating surface 39 sq. ft. / 3.6 sqM
Boiler water volume 5 gal. / 19 L
Design water flow per coil 15 gpm / 57 lpm
Air compressor requirement 2.0 CFM @ 25 PSI / 3.4m3/h @ 1.7 bar
Stack Size 8” diameter / 203 mm
Boiler cabinet dimensions 
Inches: 
Millimeters:
39.5” L x 29” W x 29” H 
1003 L x 737 W x 737 H
Approximate weight 677 lbs /304.7 kg
Electrical requirements 115 VAC 60 Hz single phase
Clean Burn CTB-350
350,000 btu used oil boiler
CTB-350-used oil boiler
CTB-350 Specifications
Maximum BTU/hr (output) 350,000 / 102 kW
Max. oil consumption/ Fuel flow rate 2.5 GPH /9.5 L/h
Acceptable Fuels Crankcase Oil, ATF, #2, #4, and #5 fuel oils, diesel oil and diesel fuel, synthetic used oil
Heating surface 68 sq. ft. / 6.3 sqM
Boiler water volume 12 gal. / 45.4 L
Design water flow per coil 25 gpm / 95 lpm
Air compressor requirement 2.5 CFM @ 25 PSI / 4.25m3/h @ 1.7 bar
Stack Size 8” diameter / 203 mm
Boiler cabinet dimensions 
Inches: 
Millimeters:
56” L x 34.25” W x 34.5” H 
1422 L x 870 W x 876 H
Approximate weight 1240 lbs /562.4 kg
Electrical requirements 115 VAC 60 Hz single phase
Clean Burn CTB-500
500,000 btu used oil boiler
CTB-500 Specifications
Maximum BTU/hr (output) 500,000 / 146.5 kW
Max. oil consumption/ Fuel flow rate 2.5 GPH /9.5 L/h
Acceptable Fuels Crankcase Oil, ATF, #2, #4, and #5 fuel oils, diesel oil and diesel fuel, synthetic used oil
Heating surface 97 sq. ft. / 9.0 sqM
Boiler water volume 20.6 gal. / 78 L
Design water flow per coil 37 gpm / 140 lpm
Air compressor requirement 2.5 CFM @ 25 PSI / 4.25m3/h @ 1.7 bar
Stack Size 10” diameter / 254 mm
Boiler cabinet dimensions 
Inches: 
Millimeters:
66.5” L x 39.75” W x 41.75” H 
1689 L x 1009 W x 1060 H
Approximate weight 1600 lbs /725.7.4 kg
Electrical requirements 115 VAC 60 Hz single phase

Click here for printable product data sheet.